The steam sampling cooler is suitable for sampling media such as liquids and vapors with high temperatures. The steam sampling cooler adopts a spiral tube (commonly known as a serpentine coil) surface cooling structure. Sampling catheters are all used for sampling, which are corrosion-resistant and non polluting.
Online inquiry
上一產(chǎn)品 : Blowdown cooler
下一產(chǎn)品 : 沒(méi)有了
  • Content details

The steam sampling cooler is suitable for sampling media such as liquids and vapors with high temperatures. The steam sampling cooler adopts a spiral tube (commonly known as a serpentine coil) surface cooling structure. The sampling tubes are all made of high-quality stainless steel tubes that are durable, corrosion-resistant, and non polluting for collecting samples, avoiding contamination by metal corrosion substances in the tubes during the sampling process. The soda sampling cooler has the advantages of compact structure, high heat transfer rate, convenient cleaning, and long use.


The steam water sampler is mainly used in the boiler and its thermal system of thermal power plants, including boiler water sampling cooling, feedwater sampling cooling, steam sampling cooling, deoxygenated water sampling cooling, condensate sampling cooling, and drainage sampling cooling. According to the division and collection of sample collection, East Power Equipment provides two types of sampling coolers: a single sampling cooler and a functional steam and water sampling cooler. The functional steam and water sampling cooler (also known as the combined steam and water sampling cooler) can simultaneously sample steam, boiler water, feedwater, and deoxygenated effluent.


The steam sampling cooler is used for cooling steam and water samples in boiler rooms or power plants. Most water in boilers and thermal systems has a high temperature, which is not convenient for sampling and measurement. Therefore, cooling should be carried out during sampling. Therefore, the sample should be introduced into the sampling cooler for cooling. The steam sampling cooler generally requires a flow rate of 500-700mL/min, and the sample can be cooled to below 30-40 degrees Celsius, meeting the standard of DL/T 457-91 in the power industry of the Republic of China


The tubes of the soda sampling cooler are made of stainless steel tube 1Cr18Ni9Ti to prevent contamination by metal corrosion products during the sampling process


1. Our steam sampling cooler is suitable for sampling media such as liquids and gases with high temperatures. It has compact structure, high heat transfer rate, convenient cleaning, and long service life.


2. Our steam sampling cooler is suitable for sampling media such as liquids and gases with high temperatures. All cooling pipes have undergone a 5-minute water pressure test of 10Mpa before leaving the factory, ensuring safe and reliable use.


3. It has compact structure, high heat transfer rate, convenient cleaning, and long usage.


4. The spiral tube of the cooler can be composed of a continuous coil with the required cooling area, or it can be arranged inside and outside of two sets of spiral tubes.


Material selection and application of soda sampling cooler--


1. The sampling tubes are all made of stainless steel (1Cr18Ni9Ti), and carbon steel pipes or brass pipes cannot be used to prevent contamination by metal corrosion products from the tubes during the sampling process


2. Our steam sampling cooler is suitable for sampling media such as liquids and gases with high temperatures. All cooling pipes have undergone a 5-minute water pressure test of 38Mpa before leaving the factory, ensuring safe and reliable use.


3. It has compact structure, high heat transfer rate, convenient cleaning, and long usage.


4. The spiral tube of the cooler can be composed of a continuous coil with the required cooling area, or it can be arranged inside and outside of two sets of spiral tubes.


The steam sampling cooler is used for cooling steam testing samples in boiler rooms or power plants. The water in boilers and thermal systems is mostly at a high temperature, which is not convenient for sampling and measurement. Therefore, cooling should be carried out during sampling. Therefore, the sampled sample should be introduced into the sampling cooler for cooling. Generally, it is required to maintain a flow rate of 500-700mL/min, and the sample can be cooled to below 30-40 degrees Celsius, meeting the standard of DL/T 457-91 in the power industry of the Republic of China.


The sampling tubes are all made of stainless steel, and carbon steel pipes or brass pipes cannot be used to prevent contamination by metal corrosion products from the tubes during the sampling process.


Soda sampling cooler is suitable for sampling media such as liquids and gases with high temperatures. It has compact structure, high heat transfer rate, convenient cleaning, and long service life.


Specification and model of soda water sampling cooler


QYL-133/0.3 QYL-159/0.35 QYL-219/0.45 0.38 QYL-273/0.55


Types of steam and water sampling coolers


1. Sampling of boiler water - usually taken from the continuous discharge pipe of the steam drum and then led to the cooler. Sampling - should be placed as close as possible to the outlet of the discharge pipe leading out of the steam drum, and as close as possible to one of the discharge valves behind the leading out of the steam drum.


2. Sampling of Water Supply The sampling of water supply is usually set after the water pump, on the high-pressure water supply pipe of the economizer, and should be connected to a small pipe on the vertical pipeline of the water supply pipe, from which the water sample is led to the sampling cooler. The sampling pipe for water supply should be located in a position that is sufficiently uniform after adding medication to the water supply.


3. Sampling of condensate: The sampling of condensate is generally located on the condensate pipeline at the outlet of the condensate pump, not at the inlet of the condensate pump, as the pressure at the inlet of the condensate pump is greater than atmospheric pressure.


4. Sampling of hydrophobic water - usually in the hydrophobic tank - sampling. Sampling - set at a distance of about 300mm from the bottom of the drainage tank.


5. Steam sample - pass through the sampling cooler to condense it into water. The steam sampler - steam flow rate - is generally 20-30kg/h. The requirements for the sample outlet duct and cooler are the same as for water sampling.


Steam sampling cooling device


The steam sampling cooler is used for cooling steam and water testing samples in boiler rooms or power plants, such as steam testing samples, boiler water testing samples, and deaerator effluent testing samples. Our company's soda sampling cooler generally uses a serpentine tube surface cooling structure.


There are two types of soda water sampling coolers: single function sampling cooler and three function sampling cooler. The three function sampling cooler can simultaneously sample steam, boiler water, and deoxygenated water. It has compact structure, high heat transfer rate, convenient cleaning, and long usage, and is used for small-scale heating and heat exchange in departments such as petroleum, chemical, light industry, and power. The cooler can also serve as a self sealing cooler for oil pumps.


purpose


The soda sampling cooler is used to cool the high-temperature soda samples for timely analysis, and is used in industries such as power and petrochemicals.


Conclusion---


Water sample collection is an important step in ensuring accurate analysis results. The steam water sampling cooler uses high-quality stainless steel as a serpentine cooling tube, which belongs to the surface heat exchange cooling structure. It has compact structure, high heat transfer rate, high strength, strong anti-corrosion ability, easy cleaning, and long use. It takes samples of power plant steam, boiler water, deaerator water quality, etc., and monitors the quality of boiler steam in a timely manner. The cooling water volume and the opening of the sampling valve should be adjusted in a timely manner during use, so that the flow rate of the water sample is adjusted between 500-700t/min, and the temperature of the water sample is between 30 ℃ and 40 ℃.


The steam sampling cooler is suitable for safe sampling and cooling of steam power plants and heating equipment for water and steam analysis, measurement of water and steam quality processes. Boilers and thermal systems have high water and steam temperatures, making it difficult to sample and measure. Therefore, cooling should be applied during sampling. The sampled sample should be introduced into the steam sampling cooler for cooling. Generally, it is required to maintain a flow rate of 500-700mL/min, and the sample can be taken below 30-40 degrees Celsius, meeting the standard of DL/T 457-91 in the power industry of the People's Republic of China. The sampling tube should be made of stainless steel, and carbon steel or brass pipes should not be used, During the sampling process, the sampling medium is corroded and contaminated by metal objects in the conduit.


Calculation of cooling area of soda sampling cooler:


1: If the sample flow rate, cooling water temperature, and initial conditions of the sample are known, the required cooling area of the steam water sampling cooler can be obtained from equation (A1):


A=f? 1.0029/3600 Δ TM? U (A1)


Equation - A - required cooling area, m2;


F - Sample flow rate, L/h;


Δ Tm - average temperature difference, ℃;


U - Overall heat exchange coefficient (U=200 for double-layer spiral tubes and immersion coolers).


When the sample is superheated steam, for every 100 ℃ superheat, the cooling area calculated by equation (A1) should be increased by 12.6%.


2: The average temperature difference can be obtained from equation (A2):


Δ Tm=[(t1-T2) - (t2-T1)]/[L (t1-T2)/(t2-T1)] (A2)


Equation- Δ Tm - average temperature difference, ℃;


T1- cooler sample temperature, ℃;


T2- cooler sample temperature, ℃;


T1- cooler - cooling water temperature, ℃;


T2- Cooling water temperature at the outlet of the cooler, ℃.


3: The spiral tube of the cooler can be composed of a group of continuous coils with the required cooling area, or it can be arranged continuously by two or more groups of spiral tubes.


The steam sampling cooler is used for cooling the steam and water laboratory samples in boiler rooms or power plants. Most of the water in boilers and thermal systems has a high temperature, which is not convenient for sampling and measurement. Therefore, cooling should be carried out during sampling. Therefore, the sampled sample should be introduced into the steam sampling cooler for cooling. Generally, it is required to maintain a flow rate of 500-700mL/min, and the sample can be cooled to below 30-40 degrees Celsius, Meet the standard of DL/T 457-91 for the power industry in the Republic of China.


Soda sampling cooler - different specifications can be arranged according to user needs for separate design schemes! Interested parties contact us!


⑴ Instructions for ordering soda water sampling coolers:


1: Indicate whether it is a steam sampling or a water sampling.


2: The working pressure and sample temperature inside the cooling tube.


3: The general selection includes two models: QYW-219/0.5 and QYL-273/0.57.


4: Do you need a combination.


⑵ Instructions for ordering soda water sampling coolers:


1: The sampler tube is made of stainless steel and the shell is made of carbon steel.


2: Sampling cooling pipes - generally choose diameters of 10, 12, 14, 16, and 18mm (or user specified). The interface can be welded or flanged, and the cooling water interface is DN25 with external threads.


3: General selection - QYL-159/0.32, QYL-219/0.40, and QYL-273/0.54.


4: Do you need a combination type (i.e. do you need brackets, sinks, valves, etc.).

汽水取樣冷卻規(guī)格型號(hào)
規(guī) 格 
型 號(hào)
管內(nèi)設(shè)計(jì)
壓力 MPa
管內(nèi)設(shè)計(jì)
溫度℃
冷卻
面積M2
蛇形盤(pán)管
/螺旋管規(guī)格
材質(zhì)
QYL-108<5.4<4500.2
?8X2
?10X2
?12X2
 
有以下材質(zhì)可供客戶選擇:

(1)外筒體:碳鋼
   盤(pán) 管:不銹鋼304

(2)外筒體:不銹鋼304
   盤(pán)  管:不銹鋼304

(3)外筒體:不銹鋼316
   盤(pán)管:不銹鋼316
 
QYL-1330.25
QYL-1590.25
QYL-2190.38
QYL-2540.45
QYL-2730.54
QYL-3250.92
QYL-159<10.0<5400.25?18X3
QYL-2190.38
QYL-2540.45
QYL-2730.69
QYL-3250.92


產(chǎn)品動(dòng)態(tài)

Soda sampling cooler生產(chǎn)廠家Copyright ? 2012-2023 Lianyungang Lingdong Electromechanical Equipment Co., Ltd all rights reserved

Tel

0518-85370171

主站蜘蛛池模板: 日本v在线观看 | 国产v的在线观看 | 91精品福利自产拍在线观看 | 国产大片B站观看 | 成人a级毛片免费播放 | 精品无码日韩一区二 | 亚洲91av视频在线观看 | 蜜臀av无码精品人妻色欲 | 精品国产国产精2024久久日 | a片无码一区二区三区在线 a片一区二区三区 | 国产人妻黑人一区二区三区 | 国产精品无码无卡a级毛片 国产精品无码无卡毛片不卡视 | 久热国产vs视频在线观看 | 么么哒日本影院 | 国产精品无码久久久久久曰本 | 精品日韩丝袜在线 | 动漫在线观看片A免费观看 都市人妻古典武侠另类校园 | 日本无人区码卡1卡2卡免费 | 国产做爰又粗又大又深人物 | 91亚洲国产第一精品 | 2024国产激情视频在 | 狠狠色噜噜狠狠狠狠98 | 无人区码一码二码三MBA智库 | 久久亚洲av无码精品色午夜麻豆 | 欧美一区二区三区精品影视 | 亚洲成人成在线观看 | 国产调教丰满欧美最近中文字幕mv高清在线 | 一二三四日本无码影视 | 五月天精品视频在线观看 | 国产乱伦在线播放 | 精品国产免费笫一区二区 | 成人爽爽激情在线观看 | 国产精品成人久久久久久久 | 国产福利麻豆91电影在线观看 | 婷婷综合亚洲 | 久久久久久久久蜜桃 | 99久久精品国产免看国产一区 | 成人黄色在线网站 | 亚洲国产午夜精华无码福利 | 九九久久精品国产免费看小说 | 婷婷丁香社区 |